PUMP CONTROL VALVE EN700X
A. PUMP CONTROL VALVE Structure and Purpose
It is used at the pump outlet to carry out an accurate open or close through the pilot control of the solenoid valve, and to prevent of the medium's back-flow. When the pump is about to stop water supply, it is closed slowly by about 90% first to prevent both water hammer and water shock noise from being produced due to sudden stop of the pump. And when the pump stops completely, it is fully closed to prevent the pump from the water's back flow so as to protect it effectively from counter movement due to the shock of the back-flow. EN700X Pump Control Valve can prevent effectively of water hammer and water shock noise. It can move reliably and stably and be used for a long time. The solenoid valve can use either AC220V or DC24V power.

B. PUMP CONTROL VALVE Brief Figure of Structure
EN700X PUMP CONTROL VALVE
EN700X PUMP CONTROL VALVE

C. PUMP CONTROL VALVE External and Connection Dimensions
EN700X PUMP CONTROL VALVE

D. PUMP CONTROL VALVE Schematic Diagram of Installation
DN(mm) 20 25 32 40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 800
L 180 180 180 203 203 235 280 360 400 455 585 650 800 860 915 980 1075 1230 1300 1450
PN10 D 105 115 135 145 160 180 195 215 245 280 335 390 440 500 565 615 670 780 895 1010
D1 75 85 100 110 125 145 160 180 210 240 295 350 400 460 515 565 620 725 840 950
PN16 D 105 115 135 145 160 180 195 215 245 280 335 405 460 520 580 640 705 840 910 1020
D1 75 85 100 110 125 145 160 180 210 240 295 355 410 470 525 585 650 770 840 950
PN25 D 105 110 135 145 160 180 195 230 270 300 360 425 485 550 610 660 730 840 955 1070
D1 75 85 100 110 125 145 160 190 220 250 310 370 430 490 550 600 660 770 875 990
H 342 342 342 395 395 405 430 510 560 585 675 730 760 840 910 1070 1135 1270 1460 1640
H1 247 247 247 278 278 298 313 350 365 420 450 470 490 526 570 610 665 725 865 975
Note: Either elastic seat ring sealed gate valve or butterfly valve can be selected in the schematic of installation. Recommend to select the butterfly valve in case of =DN350

E. PUMP CONTROL VALVE Main Technical Features
Nominal Pressure 1.0MPa 1.6MPa 2.5MPa
Shell test pressure 1.5MPa 2.4MPa 3.75MPa
Sealed test pressure 1.1MPa 1.76MPa 2.75MPa
Suitable temperature ≤80℃
Suitable medium water